Description
PL 12-3 7151OT LT is a PrimeLine luminaire, length 1270 mm, power 64.7 W, Transparent diffuser. PrimeLine ATEX emergency light with battery (1.5 h, self-contained). Certification covers Zones 1, 2, 21 and 22. This SKU is the battery variant only, not generic ATEX emergency lighting. GRP body, PC diffuser, IP66/IP67. Selected LT versions operate from −20 °C; confirm the exact product code.
Technical specification
| Ordering code | PL 12-3 7151OT LT |
|---|---|
| Dimensions L×D×H | 1270x173x107 |
| Power | 64.7 W |
| Luminous flux AC | 8305 lm |
| Luminous flux DC (emergency) | 750 lm |
| Colour temperature | 4000 K |
| CRI | >80 |
| IP | IP66 / IP67 |
| IK | IK09 |
| Housing | GRP |
| Diffuser | Transparent (PC) |
| Cable glands | M25 — 1 gland, one side |
| Terminals | 7-pole |
| Through wiring | Not applicable |
| Isolating switch | no |
| Ambient temperature | -20°C… +40°C |
| ATEX / IECEx | Ex II 2G Ex eb mb IIC T4 Gb – Ex II 2D Ex tb IIIC T70°C Db |
| Zone | 1 |
Code PL 12-3 7151OT LT means: 1270 mm, ~14 W LED module, 7-pole terminal, M25 (1 gland, one side), internal NiCd battery, 1.5 h, no isolating switch, transparent diffuser, heater LT.
Applications and limitations
- self-contained NiCd battery variant — not general or central-battery lighting;
- replace the battery only outside the hazardous atmosphere, per the instruction;
- emergency duration for this SKU: 1.5 h;
- take photometric and Ex data from this SKU / nameplate — do not generalise the whole family;
- install per IEC 60079-14 and the instruction for the exact version (S/B, 1/3 or X/Y);
- final selection must be made by a competent person for the installation.
Documents
- ATEX certificate KSCP 25ATEX0029X
- IECEx certificate KSCP 25.0045X
- EU Declaration of Conformity — PrimeLine
- PrimeLine data sheet
- Operating instruction (SKU version)
- Photometry package
- CNBOP certificate 6090/2026
FAQ
Does this luminaire have ATEX and IECEx certificates?
Yes. PrimeLine is covered by ATEX KSCP 25ATEX0029X and IECEx KSCP 25.0045X. Take the full Ex marking and temperature from the nameplate / this SKU.
Which zones is it intended for?
Certification covers gas Zones 1 and 2 and dust Zones 21 and 22. In the shop the Zone attribute for PrimeLine is 1. Final selection depends on the installation documents.
What is the ambient temperature range?
For PL 12-3 7151OT LT: -20°C… +40°C. HT/LT suffixes change the range — always confirm in the product code.
What is the emergency duration?
For this SKU: 1.5 h. Do not assign both values to one code.
How does general lighting differ from emergency variants?
Code S = general. Codes 1/3 = internal battery (1.5 h / 3 h). Codes B/X/Y = central battery. These are separate SKUs and category children.
What luminous flux and power does PL 12-3 7151OT LT have?
PL 12-3 7151OT LT: 64.7 W, mains luminous flux 8305 lm, emergency mode 750 lm. Wide symmetric distribution of approx. 115°. For lighting design (e.g. DIALux) use the photometric file of this code under Documents.
How many cable glands and stopping plugs does this luminaire need?
The luminaire has 1 M25 entry (1 gland, one side). Each needs a certified Ex cable gland matched to the cable diameter, and an unused one a certified stopping plug; an ordinary gland or plug breaches the luminaire certificate. Ex glands and stopping plugs are in the AtexBox gland accessories category.
Can supply be looped through this luminaire?
No. Glands are on one end only — for through-wiring choose a version with glands at both ends (1+1, 2+1 or 2+2).
Does this luminaire have an isolating switch, and what is its Ex marking?
No — the isolating switch is not available on 1.5 h and 3 h battery versions. Gas marking: II 2G Ex eb mb IIC T4 Gb.
Which battery does this luminaire have?
NiCd battery, emergency duration 1.5 h. The LT version has a heater and operates from −20 °C. The battery is not replaced in an explosive atmosphere — replace per the series instruction.
How is it built, and where is it used?
GRP body, UV-stabilised polycarbonate diffuser, IK09, IP66/IP67; the diffuser and LED plate are hinged, so nothing has to be set aside when opening. Ambient temperature for this code: -20°C… +40°C. Typical locations: loading ramps, unheated warehouses, cold stores (with the version matched to temperature) and chemical and petrochemical plants.
Where can I download the certificate and instructions?
See Documents on this page: ATEX, IECEx, EU declaration, data sheet, version-specific instruction and photometry.
Other PrimeLine lengths / powers — Internal battery 1.5 h · Transparent diffuser
Same function subcategory and the same terminals, gland layout and diffuser. Length and LED module vary. The current SKU is highlighted.
| SKU | Length | Module | Power | Flux AC |
|---|---|---|---|---|
PL 60-1 7151OT LT |
670 mm | 1 | 27.5 W | 2946 lm |
PL 60-2 7151OT LT |
670 mm | 2 | 31.6 W | 3613 lm |
PL 12-2 7151OT LT |
1270 mm | 2 | 56.5 W | 7293 lm |
PL 12-3 7151OT LT |
1270 mm | 3 | 64.7 W | 8305 lm |






Reviews
There are no reviews yet.