Armoured
Armoured ATEX cable glands (HARDO HCG2) are double-compression metal glands for circular SWA/SWB armoured cables. They seal the inner and outer sheath and clamp the armour. Certified ATEX/IECEx for Zones 1, 2, 21 and 22 — Ex db / Ex eb / Ex tb, IP66/IP68, −55°C … +160°C, metric M20–M90 or NPT.
To select: armour type (SWA/SWB) · entry thread (metric / NPT) · under-armour Ø A + overall Ø B · material · Ex marking and certificates. Not for unarmoured cable — use Non-armoured (HCG1).
Showing 1–12 of 82 results
How to use the selection filters
The left-hand panel (on phones: the Selection button) narrows the HARDO cable-gland catalogue. Set parameters in engineering order — from cable type to diameter.
Non-armoured → HCG1 series. Armoured (SWA/SWB) → HCG2. On armoured/non-armoured child categories this filter is already fixed.
Choose metric or NPT to match the enclosure entry. Do not mix systems — thread sizes follow the selected family.
Set the thread size (e.g. M20, M25…) and material: brass, nickel-plated brass or stainless steel 316L. Multiple values are allowed — the grid shows products that match.
Overall Ø — outer cable diameter. For armoured glands also use Under sheet Ø. Only glands whose sealing range covers the value remain.
- Set cable type (or open the armoured / non-armoured subcategory).
- Match thread family to the enclosure entry (metric / NPT). M16 entry: HAD adaptor + M20 gland.
- Choose thread size and gland material.
- Enter cable OD (and under-sheet OD for HCG2 when needed).
- Click Find matching glands — the product grid updates.
- Open the SKU card and verify sealing code, Ex marking and documents.
- Above the grid, Selected specification chips appear — × removes one parameter.
- Clear in the panel resets the whole selection.
- On mobile the filter panel opens as a Bootstrap offcanvas (Selection button).
- The apply button shows how many glands match before you confirm.
- They do not replace checking the ATEX/IECEx certificate and installation instruction.
- They do not auto-add an HAD adaptor — for M16 add it separately.
- Final selection must be made by a competent person with the full installation documentation.
HCG2 — cable ranges (armoured)
Table for armoured HCG2 glands. The CODE column shows nickel-plated brass (N) examples;
the same Ø ranges apply to brass (B) and stainless 316L (S) for the same sealing code.
Cable diameter under the armour (bedding), min–max [mm].
Outer cable diameter (overall / outer sheath), min–max [mm].
Thread length E [mm] — entry length into the enclosure (metric or NPT).
How to read: under-armour Ø → column A; overall Ø → column B. Both must match the same row.
| CODE | METRIC | E [mm] | A — under armour Ø [mm] | B — overall Ø [mm] | ||
|---|---|---|---|---|---|---|
| min | max | min | max | |||
| HCG2N1M20XS | M20 | 17 | 3.2 | 8.5 | 6.2 | 13.1 |
| HCG2N1M20S | M20 | 17 | 6.2 | 11.6 | 9.6 | 15.5 |
| HCG2N1M20 | M20 | 17 | 8.0 | 13.9 | 12.5 | 20.9 |
| HCG2N2M25S | M25 | 17 | 11.2 | 19.6 | 14.0 | 21.5 |
| HCG2N2M25 | M25 | 17 | 11.2 | 19.6 | 18.3 | 25.6 |
| HCG2N3M32 | M32 | 17 | 17.1 | 26.0 | 23.7 | 33.4 |
| HCG2N4M40 | M40 | 17 | 22.1 | 31.6 | 28.0 | 39.5 |
| HCG2N5M50S | M50 | 17 | 29.5 | 37.5 | 35.2 | 46.0 |
| HCG2N5M50 | M50 | 17 | 35.6 | 43.1 | 40.5 | 52.4 |
| HCG2N6M63S | M63 | 17 | 40.1 | 48.7 | 45.6 | 58.5 |
| HCG2N6M63 | M63 | 17 | 47.2 | 55.2 | 54.6 | 64.5 |
| HCG2N7M75S | M75 | 17 | 52.8 | 61.2 | 59.0 | 70.4 |
| HCG2N7M75 | M75 | 17 | 59.1 | 67.2 | 66.7 | 76.3 |
| HCG2N9M90 | M90 | 24 | 66.6 | 79.2 | 76.2 | 87.2 |
| CODE | NPT | E [mm] | A — under armour Ø [mm] | B — overall Ø [mm] | ||
|---|---|---|---|---|---|---|
| min | max | min | max | |||
| HCG2N1N20XS | 3/8″ | 20 | 3.2 | 8.5 | 6.2 | 13.1 |
| HCG2N1N20S | 1/2″ | 20 | 6.2 | 11.6 | 9.6 | 15.5 |
| HCG2N1N20 | 1/2″ | 20 | 8.0 | 13.9 | 12.5 | 20.9 |
| HCG2N2N25S | 3/4″ | 21 | 11.2 | 19.6 | 14.0 | 21.5 |
| HCG2N2N25 | 3/4″ | 21 | 11.2 | 19.6 | 18.3 | 25.6 |
| HCG2N3N32 | 1″ | 26 | 17.1 | 26.0 | 23.7 | 33.4 |
| HCG2N4N40 | 1 1/4″ | 26 | 22.1 | 31.6 | 28.0 | 39.5 |
| HCG2N5N50S | 1 1/2″ | 26 | 29.5 | 37.5 | 35.2 | 46.0 |
| HCG2N5N50 | 2″ | 27 | 35.6 | 43.1 | 40.5 | 52.4 |
| HCG2N6N63S | 2″ | 27 | 40.1 | 48.7 | 45.6 | 58.5 |
| HCG2N6N63 | 2 1/2″ | 40 | 47.2 | 55.2 | 54.6 | 64.5 |
| HCG2N7N75S | 2 1/2″ | 40 | 52.8 | 61.2 | 59.0 | 70.4 |
| HCG2N7N75 | 3″ | 42 | 59.1 | 67.2 | 66.7 | 76.3 |
| HCG2N9N90 | 3 1/2″ | 44 | 66.6 | 79.2 | 76.2 | 87.2 |
Ø ranges from HARDO pricelist / product meta. Thread length E and NPT designations from the HCG2 data sheet. Filter Under sheet Ø = column A; Overall Ø = column B.