PrimeLine 670 mm 23.4 W | Opal | M25 | General

290,13 €
Type
General lighting
Zone (attribute)
1
Length
670 mm
Power
23.4 W
Flux AC
2375 lm
Diffuser
Opal
Glands
M25 / 2 glands on one side and 1 on the other
Ambient
-40°C…+45°C
IP
IP66 / IP67

Ex II 2G Ex db eb mb IIC T4 Gb – Ex II 2D Ex tb IIIC T70°C Db

SKU: PL 60-1 335SRO
Category: , ,

Description

PL 60-1 335SRO is a PrimeLine luminaire, length 670 mm, power 23.4 W, Opal diffuser. PrimeLine ATEX Zone 1 light fittings. Linear Ex LED luminaire for general lighting. Certification also covers Zones 2, 21 and 22. GRP body, PC diffuser, IP66/IP67. This SKU does not include emergency variants.

Technical specification

Parameters PL 60-1 335SRO
Ordering code PL 60-1 335SRO
Dimensions L×D×H 670x173x107
Power 23.4 W
Luminous flux AC 2375 lm
Colour temperature 4000 K
CRI >80
IP IP66 / IP67
IK IK09
Housing GRP
Diffuser Opal (PC)
Cable glands M25 — 2 glands on one side and 1 on the other
Terminals 3-pole
Through wiring 2.5 mm² / 105°C insulation
Isolating switch yes
Ambient temperature -40°C…+45°C
ATEX / IECEx Ex II 2G Ex db eb mb IIC T4 Gb – Ex II 2D Ex tb IIIC T70°C Db
Zone 1

Code PL 60-1 335SRO means: 670 mm, ~10 W LED module, 3-pole terminal, M25 (2 glands on one side and 1 on the other), general lighting, with isolating switch, opal diffuser.

Applications and limitations

  • general lighting only (code S) — not internal-battery or central-battery variants;
  • take photometric and Ex data from this SKU / nameplate — do not generalise the whole family;
  • install per IEC 60079-14 and the instruction for the exact version (S/B, 1/3 or X/Y);
  • final selection must be made by a competent person for the installation.

Documents

FAQ

Does this luminaire have ATEX and IECEx certificates?

Yes. PrimeLine is covered by ATEX KSCP 25ATEX0029X and IECEx KSCP 25.0045X. Take the full Ex marking and temperature from the nameplate / this SKU.

Which zones is it intended for?

Certification covers gas Zones 1 and 2 and dust Zones 21 and 22. In the shop the Zone attribute for PrimeLine is 1. Final selection depends on the installation documents.

What is the ambient temperature range?

For PL 60-1 335SRO: -40°C…+45°C. HT/LT suffixes change the range — always confirm in the product code.

How does general lighting differ from emergency variants?

Code S = general. Codes 1/3 = internal battery (1.5 h / 3 h). Codes B/X/Y = central battery. These are separate SKUs and category children.

Where can I download the certificate and instructions?

See Documents on this page: ATEX, IECEx, EU declaration, data sheet, version-specific instruction and photometry.

Other PrimeLine lengths / powers — General lighting · Opal diffuser

Same function subcategory and the same terminals, gland layout and diffuser. Length and LED module vary. The current SKU is highlighted.

SKU Length Module Power Flux AC
PL 60-1 335SRO 670 mm 1 23.4 W 2375 lm
PL 60-2 335SRO 670 mm 2 28.0 W 2913 lm
PL 60-3 335SRO 670 mm 3 32.4 W 3374 lm
PL 12-1 335SRO 1270 mm 1 43.0 W 4820 lm
PL 12-3 335SRO 1270 mm 3 62.0 W 6696 lm

Additional information

Type

Zone

Length

670 mm

Diffuser

Gland size

Gland layout

Terminals

Isolating switch

Through wiring

Colour temperature

Ex protection

,

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.