Motor switch 0.25–0.4 A | 4 × M25 | U + aux

555,29 

II 2 G Ex db eb IIC T4/T5/T6 Gb · II 2 D Ex tb IIIC T85°C Db

SKU: HCS1P 252616 S01234
Category: , ,

Description

HARDO HCS1P motor circuit breaker for Ex zones 1, 2, 21 and 22. Five protections (overload, short-circuit, thermal, phase loss; undervoltage optional). Large Ø 97 mm knob, operable with gloves; lockable in OFF. GRP enclosure, IP66, 440 V, AC-3 up to 25 A.

  • Overload trip range: 0.25–0.4 A
  • Cable glands: 4 × M25
  • Undervoltage trip (U): Yes
  • Auxiliary contacts 1NO+1NC: 1NO+1NC
  • ATEX: II 2 G Ex db eb IIC T4/T5/T6 Gb · II 2 D Ex tb IIIC T85°C Db
  • IECEx: Ex db eb IIC T5/T6 Gb · Ex tb IIIC T85°C Db
  • Zones: 1, 2 (gas) · 21, 22 (dust)
  • Ambient temperature: -40°C to +55°C
  • IP: IP66
  • Voltage / category: 440 V · AC-3 25 A
  • Rated switching capacity: 65 kA
  • Dimensions (H×W×D): 250 × 260 × 160 mm
  • Weight: 6.25 kg
  • Main contacts: 1–10 mm² (6–10 mm² with collets)
  • Auxiliary contacts: 1–2.5 mm² · AC15 1 A / 230 V
  • Knob: Ø 97 mm, padlockable in OFF

Code HCS1P 252616 S01234 means: enclosure HCS1P 252616 (250 × 260 × 160 mm) · overload 0.25–0.4 A · glands 4 × M25 · option U + aux.